EMC New 2021 DEA-41T1 Test Tutorial (Updated 120 Questions)
DEA-41T1 Exam Questions Dumps, Selling EMC Products
Dell DEA-41T1: Associate - PowerEdge Exam salary
The average salary of a Dell Specialist - Implementation Engineer PowerEdge MX Modular Certified Expert in:
- Europe - 85,500 EURO
- India - 19,50,500 INR
- United State - 115,500 USD
- England - 86,600 POUND
NEW QUESTION 35
Why is it mandatory practice to review the service manual prior to replacing or reseating components on a Dell EMC PowerEdge server?
- A. Service crucial cable routing and special part handling instructions.
- B. Service manual gives detailed instruction at which firmware levels the components should run
- C. Service manual describes has to reconfigure the server for option performnance-bossting settings, increasing efficiency
- D. Service manual provides virtual information on which live wire in the system to avoid, to ensure electric shocks does not accrue Service manual
Answer: C
NEW QUESTION 36
A server administrator needs to change the settings of their iDRAC utilizing just the front panel.
Which configuration would allow this?
- A. LED Only
- B. LED with Quick Sync 2
- C. LCD Only
- D. Both LCD and LED
Answer: D
NEW QUESTION 37
What is an accurate statement regarding 40 Gbps Ethernet ports?
- A. Must be segmented into four independent 10 Gb connections
- B. Cannot be configure into a stack connection
- C. May only be used as a non-negotiable single 40 Gb link
- D. Can be used as a single Gb connection or used as four 10 Gb connections
Answer: D
NEW QUESTION 38
A system administrator is tasks with troubleshooting a connectivity issue with a CMC module. Connection through a wired Ethernet connection is not possible.
Which alternative connection method should the administrator use?
- A. Serial
- B. Wireless
- C. SSH
- D. NFC
Answer: A
NEW QUESTION 39
A system administrator notices that a client system cannot access the Internet. The IP address is
169.254.10.26. The client system is correctly wired.
Which server role should the administrator investigate?
- A. TCP/IP
- B. DHCP
- C. SNMP
- D. PROXY
Answer: B
NEW QUESTION 40
A customer requires an external storage for their Dell EMC PowerEdge server which allows them to efficiently share files between systems.
What type of storage will meet the requirement?
- A. SAN
- B. SDS
- C. NAS
- D. DAS
Answer: C
NEW QUESTION 41
Based on the exhibit, Grid Redundant Mode is selected on a Dell EMC PowerEdge server and the Hot Spare feature is disabled. How is the power output distributed in a dual-power supply configuration?
- A. Only one power supply ever provides power
- B. power supply 2 only provides output when power supply 1 reaches maximum capacity
- C. Majority of the output is always provided by power supply 1
- D. Equally across both power supplies
Answer: D
NEW QUESTION 42
What is the amount of hard drives request per RAID set, when configure RAID 50?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 43
Why is it mandatory practice to review the service manual prior to replacing or reseating components on a Dell EMC PowerEdge server?
- A. Service manual gives detailed instruction at which firmware levels the components should run
- B. Service manual describes has to reconfigure the server for option performnance-bossting settings, increasing efficiency
- C. Service crucial cable routing and special part handling instructions.
- D. Service manual provides virtual information on which live wire in the system to avoid, to ensure electric shocks does not accrue Service manual
Answer: C
NEW QUESTION 44
Refer to the exhibit.
An administrator has a standalone M1000e chassis with only a single CMC module. The CAT6 cable is plugged into the Ethernet port closest to the DB-9 connector. The power indicator light is lit but the administrator is unable to access the CMC module.
What could be the cause of this issue?
- A. No DB-9 serial cable is plugged in
- B. CAT5 cable is required for connection to CMC
- C. CAT6 cable into the stacking port
- D. CMC module was removed without powering off the chassis
Answer: A
Explanation:
Explanation/Reference:
Reference: https://topics-cdn.dell.com/pdf/poweredge-m1000e_owners-manual_en-us.pdf
NEW QUESTION 45
Which solution is used as a one-to-one systems management?
- A. OME-M
- B. OME
- C. OMSA
- D. SAE
Answer: C
NEW QUESTION 46
Whatis a consideration for a hardware administrator who is physically is physically installing multiple servers into a rack?
- A. Avoid unevenly loading the rack and creating a hazard
- B. Ensure that the associated UPS can also power the top-ofrack switch
- C. Observe load requirements specified in document for the switch
- D. Ensure that the server can connect to Windows updates
Answer: B
NEW QUESTION 47
A customer created a RAID 6 volume using 4x 600GB disks. How much usable disk space is available?
- A. 2.4TB
- B. 600GB
- C. 1.8TB
- D. 1.2TB
Answer: D
Explanation:
Explanation/Reference: https://www.icc-usa.com/raid-calculator/
NEW QUESTION 48
Which RAID level requires a minimum of four hard drives?
- A. RAID 5
- B. RAID 6
- C. RAID 0
- D. RAID 1
Answer: B
Explanation:
Explanation/Reference: https://www.enterprisestorageforum.com/sans/features/article.php/3855631/RAID-Storage-Levels- Explained.htm
NEW QUESTION 49
Where in the iDRAC GUI can the recording of the last three boot cycles of a Dell EMC PowerEdge server be found?
- A. Troubleshooting > Lifecycle Log
- B. Maintenance > Troubleshooting
- C. Maintenance > Diagnostics
- D. Troubleshooting > SupportAssist
Answer: B
NEW QUESTION 50
A customer looks for a storage solution to boot the hypervisor, where one is active and the other standby.
Which solution will allow the requirement?
- A. BOSS
- B. BIOS
- C. UEFI
- D. IDSDM
Answer: A
NEW QUESTION 51
A system administrator is unable to install Hyper_V on a Microsoft server 2016. What is a possible reason for this issue?
- A. System, is equipped with a 64-bit processor
- B. System has 2 GB memory
- C. Virtualization feature turned on in BIOS
- D. Standard license is installed
Answer: A
NEW QUESTION 52
Which initial option should be chosen from the iDRAC Virtual Console to access System Setup?
- A. Next Boot
- B. Virtual CD/DVD
- C. Lifecycle Controller
- D. Normal Boot
Answer: A
NEW QUESTION 53
What is a benefit of having Uninterruptible Power Supply (UPS) attached to a server?
- A. Keeps a server running during a long power outage
- B. Provides permanent power to a server, eliminating the need for a wall outlet
- C. Provides short-term protection to allow a server to be down gracefully
- D. Replaces the need for power supplies in a server
Answer: C
NEW QUESTION 54
What benefit is offered by modular servers over rack servers?
- A. Lower power requirements result in lower datacenter operating costs.
- B. All hardware technology is integrated into a single circuit board
- C. Hot replacement of any server in the enclosure is possible
- D. Higher density is achieved by reducing the amount of consumed rack space
Answer: D
Explanation:
Explanation/Reference:
Reference: https://www.racksolutions.com/news/data-center-optimization/blade-server-vs-rack-server/
NEW QUESTION 55
Based on the exhibit,
Which type of virtual switch is vswitch1?
- A. Private
- B. Public
- C. External
- D. Open
Answer: A
NEW QUESTION 56
A network administrator has to reconfigure the company firewall to allow access to a website on the internet.
Which technology will provide the administrator with the correct IP address?
- A. DNS
- B. ARP
- C. DHCP
- D. HTTP
Answer: D
NEW QUESTION 57
What are characteristics of a UTP Ethernet cable?
- A. High noise and higher costs
- B. Less susceptible to noise and lower costs
- C. High noise and lower costs
- D. Less susceptible to noise and higher costs
Answer: C
NEW QUESTION 58
An administrator needs to set up a RAID which requires high performance but no data protection.
Which RAID level fulfills these requirements?
- A. RAID 0
- B. RAID 5
- C. RAID 6
- D. RAID 1
Answer: A
Explanation:
RAID 0 provides somewhat better performance than 5 or 1/10 but offers no data protection. In larger transfer size environments, RAID 1/10 performances can be slightly better than RAID 5 but has a much higher disk- cost.
NEW QUESTION 59
A General GPU (GPGPU) is commonly install in Dell EMC PowerEdge servers. Which component does a GPGPU complement when processing tasks?
- A. Memory
- B. iDRAC modules
- C. CPU
- D. Network Interface Cards
Answer: C
NEW QUESTION 60
......
Training Course for DEA-41T1 Exam
Dell EMC also provides applicants with an on-demand learning option that portrays the expectations of DEA-41T1 exam. The estimated length of the course is 3.5 hours and it largely concerns the concepts around Dell PowerEdge server. During the program, you will get introduced to PowerEdge as well as products and technologies associated with it. Thus, it brings out the steps involved when executing, managing, maintaining, and securing current technologies, which helps to get completely ready for the test.
DEA-41T1 Cert Guide PDF 100% Cover Real Exam Questions: https://www.examslabs.com/EMC/EMC-DECA-PowerEdge/best-DEA-41T1-exam-dumps.html
Pass DEA-41T1 Review Guide, Reliable DEA-41T1 Test Engine: https://drive.google.com/open?id=1ILs16js-nTMTPLakWrDV2njHv1pQ1A64