NABCEP PV Installation Professional (PVIP) Board Certification - PVIP Exam Practice Test

A maintenance inspection reveals cracked module glass. What is the immediate action?
Correct Answer: A
A PV system requires labeling per NEC 690.56. Which of the following must be posted at the point of interconnection?
Correct Answer: B
A technician has been called to a scale due to a low-performing array. The technician will perform tests in the
24-source circuit combiner box. After putting on the correct PPE and turning off and performing lock.tagout of the inverted and combiner disconnect. Which is the next step to safely begin electrical testing in the combiner box?
Correct Answer: C
A PV system operates at 800V DC. What is the minimum distance for unqualified personnel per NFPA 70E restricted approach boundary?
Correct Answer: D
Which of the following tests measures axial uplift when performing load testing of driven-pile foundation members
Correct Answer: B
A rooftop PV system is being installed on a residential building with a 30-degree tilt angle. The modules are oriented directly south in a location where the solar noon altitude on December 21st is 30 degrees. What is the minimum distance required between two rows of modules to avoid shading between 9 AM and 3 PM solar time, assuming the module height is 3 feet?
Correct Answer: B
A 15 kW system has a total derate factor of 0.87. After 3 years at 1% degradation/year, what is the output?
Correct Answer: B
An 8 AWG bare copper equipment ground conductor (EGC) is wire tied to the module mounting structure of a commercial rooftop solar array. After a few years of operation, some spots on the EGCbegin to turn a green color and appear to be corroding more significantly that other places. What would the MOST likely cause of the problem?
Correct Answer: B
An installer is working on a 1000V DC PV array. What is the minimum PPE required per NFPA 70E for arc flash protection?
Correct Answer: D
A 20 kW system has a measured output of 18 kW at STC. What is the total system loss?
Correct Answer: B
A 7KW/ 14 KWh multimode system has been installed at a residence, ac-couple with the customer's existing
6.7kwh ac PV system. The system providers uninterrupted power to a protect loads subpanel, which is connected to a refrigerator, Microwave, 1.0 ton are conditioner, three lightning circuit, and the 6.7kwac PV system. One month later, the homeowner moves additional circuits to the protected loads subpanel, substantially increasing the loads. Why would this cause, the backfed interconnection breaker in the main service panel to trip?
Correct Answer: B
A bank of batteries with capability of supplying 250A and a maximum voltage of 325V is housed in a concrete structure in a very humid location. There is service access alsie between rows of batteries. What is the REQUIRED safety distance between the rows of batteries.
Correct Answer: A
A PV module has a NOCT of 47°C. At 1000 W/m² and 35°C ambient, what is the cell temperature?
Correct Answer: D
A PV module shows burn marks near the junction box. What is the most likely cause?
Correct Answer: B
A system's inverter output is 9 kW at 900 W/m² irradiance. What is the expected output at 1000 W/m²?
Correct Answer: C