Network Appliance Cisco and NetApp FlexPod Implementation and Administration - NS0-176 Exam Practice Test
When trying to configure a Virtual Port Channel (vPC), what might be a cause of the following error when trying to create the vPC domain?
Nexus-5548-B(config)# vpc domain 10
^% Invalid command at '^' marker.Nexus-5548-B(config)#
Nexus-5548-B(config)# vpc domain 10
^% Invalid command at '^' marker.Nexus-5548-B(config)#
Correct Answer: B
A Cisco UCS chasis has two power suppliers connected to one PDU and two power supplies connected to another PDU. You would like to protect against the failure of one entire PDU.
In this scenario, which power policy should you configure in UCS Manager?
In this scenario, which power policy should you configure in UCS Manager?
Correct Answer: D
How many ACTIVE SPAN sessions exist on a Fabric Interconnect?
Correct Answer: D
A customer uses Cisco Intersight and now wants to monitor their NetApp storage system with Intersight.
In this scenario, which three actions must be completed to accomplish this task? (Choose three.)
In this scenario, which three actions must be completed to accomplish this task? (Choose three.)
Correct Answer: B,C,D
You are installing a FlexPod Express solution with a NetApp AFF A250 at a customer's remote site.
In this scenario, which two devices are required to provide an NFS v3 datastore? (Choose two.)
In this scenario, which two devices are required to provide an NFS v3 datastore? (Choose two.)
Correct Answer: B,D
Your UCS environment has recently been upgraded to include UCS B-Series Servers, UCS C-Series Servers, a UCS mini, and a fourth UCS domain. With these new changes, you need a management tool to help you manage the entire environment from a single location.
In this scenario, which tool would you use?
In this scenario, which tool would you use?
Correct Answer: A
Exhibit:

An administrator is building a FlexPod configuration with UCS 6296 Fabric Interconnect devices that support legacy Fibre Channel 9FC) connections. The administrator uses UCS Manager to configure the unified ports on the Fabric Interconnect.
Referring to the exhibit, how many ports will FC use after the configuration is completed?

An administrator is building a FlexPod configuration with UCS 6296 Fabric Interconnect devices that support legacy Fibre Channel 9FC) connections. The administrator uses UCS Manager to configure the unified ports on the Fabric Interconnect.
Referring to the exhibit, how many ports will FC use after the configuration is completed?
Correct Answer: C
You are asked to verify your MPIO settings for your ONTAP FlexPod solution. You are using VMware ESXi 6 and FCP as the storage protocol.
In this scenario, which MPIO setting would you use on the ESXi host?
In this scenario, which MPIO setting would you use on the ESXi host?
Correct Answer: C
Under which tab in UCS Manager would you create a boot policy?
Correct Answer: C