Dell SC Series Storage Professional - DSDSC-200 Exam Practice Test
On the first day after the Storage Center is installed, the engineer begins copying data to it.
The engineer uses the default Replay Profile and Data Progression settings. The engineer notices that the system did take replays, but no data has been restriped in Tier 1.
What is the cause of the problem?
The engineer uses the default Replay Profile and Data Progression settings. The engineer notices that the system did take replays, but no data has been restriped in Tier 1.
What is the cause of the problem?
Correct Answer: D
In the setup wizard, which three options are available to choose how the Storage Center handles software updates? (Choose three.)
Correct Answer: A,B,C
An engineer installed die Dell Storage Manager Server Agent on a Windows 2008 R2 server. The engineer configured White Space Recovery for the specific server, but recovery is NOT completing successfully when it is scheduled to run.
What should the engineer change to allow White Space Recovery to run. successfully?
What should the engineer change to allow White Space Recovery to run. successfully?
Correct Answer: B
A customer plans to use an SC8000 unit for long-term storage of CCTV security video recordings. Thus system consists of 84 - 4TB 7k disks. The customer does not plan to take any replays on the system.
Which setup should be recommended to meet the customer's requirements?
Which setup should be recommended to meet the customer's requirements?
Correct Answer: A
An engineer receives an alert that the Storage Center has entered Conservation mode.
How should the engineer respond to the alert?
How should the engineer respond to the alert?
Correct Answer: C
A customer has an 8 TB database. Half of the data is hot with very frequent access The other half of the data is older, infrequently used cold data The customer buys (12) 800 GB
SLC Solid State Drives, and puts them in a new disk folder called "Database" The customer then creates volumes for this database in the Database disk folder using the recommended storage profile.
After this database has been running for 1 month, the Statistics tab for the database volumes shows 100% of the space is on Tier 1. The customer expected that half of the data would be on Tier 1 and the rest moved to lower tiers.
What is the problem?
SLC Solid State Drives, and puts them in a new disk folder called "Database" The customer then creates volumes for this database in the Database disk folder using the recommended storage profile.
After this database has been running for 1 month, the Statistics tab for the database volumes shows 100% of the space is on Tier 1. The customer expected that half of the data would be on Tier 1 and the rest moved to lower tiers.
What is the problem?
Correct Answer: B
A engineer needs to use the Storage Center setup wizard to complete the local port configuration. The engineer needs to select a value for 'Purpose' for SAS/FC ports that are directly connected between the two system controllers. Which value should the engineer select?
Correct Answer: B
An engineer is installing an SC4020 with four fibre channel (FC) ports in each controller and two FC switches configured in a dual fabric. The replication ports on the controller will be used only to replicate data to another Storage Center
How many fault domains are required in Virtual Port mode?
How many fault domains are required in Virtual Port mode?
Correct Answer: A
A storage administrator is setting up replication between two Storage Centers for the first time and needs to determine the proper zoning for the two systems to communicate. Both
Storage Centers are using Virtual Port mode.
Which three zones are the proper zones to set up m each fabric? (Choose three.)
Storage Centers are using Virtual Port mode.
Which three zones are the proper zones to set up m each fabric? (Choose three.)
Correct Answer: A,D,E